|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
200W Single Output with PFC Function Features : HRPG-200 series Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit 1U low profile 38mm Built-in remote ON-OFF control Standby 5V@0.3A Built-in remote sense function No load power consumption<0.5W (Note.6) 5 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE HRPG-200-3.3 HRPG-200-5 3.3V 40A 0 ~ 40A 132W 5V 35A 0 ~ 35A 175W 90mVp-p 4.3 ~ 5.8V 2.0% 0.5% 1.0% HRPG-200-7.5 HRPG-200-12 HRPG-200-15 HRPG-200-24 HRPG-200-36 HRPG-200-48 7.5V 26.7A 0 ~ 26.7A 200.3W 100mVp-p 6.8 ~ 9V 2.0% 0.5% 1.0% 12V 16.7A 0 ~ 16.7A 200.4W 120mVp-p 10.2 ~ 13.8V 1.0% 0.3% 0.5% 15V 13.4A 0 ~ 13.4A 201W 150mVp-p 13.5 ~ 18V 1.0% 0.3% 0.5% 24V 8.4A 0 ~ 8.4A 201.6W 150mVp-p 21.6 ~ 28.8V 1.0% 0.2% 0.5% 36V 5.7A 0 ~ 5.7A 205.2W 250mVp-p 28.8 ~ 39.6V 1.0% 0.2% 0.5% 48V 4.3A 0 ~ 4.3A 206.4W 250mVp-p 40.8 ~ 55.2V 1.0% 0.2% 0.5% RIPPLE & NOISE (max.) Note.2 80mVp-p 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) 0.5% 1.5% 16ms/230VAC 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load 16ms/115VAC at full load 120 ~ 370VDC PF>0.99/115VAC at full load 86% 88% 88% 88% 89% 89% 1.1A/230VAC 70A/230VAC VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE 5V STANDBY REMOTE CONTROL WORKING TEMP. PF>0.95/230VAC 80% 2.2A/115VAC 35A/115VAC <1.2mA / 240VAC 84% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 3.96 ~ 4.62V Protection type : Shut down o/p voltage, re-power on to recover 95 105 5 5 (TSW1) detect on heatsink of power transistor (TSW2) detect on main power output choke 57.6 ~ 67.2V FUNCTION Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.) RC+/RC- : 4 ~10V or open = power on ; 0 ~ 0.8V or short = power off -30 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT EMS IMMUNITY MTBF ISOLATION RESISTANCE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A 189.1K hrs min. MIL-HDBK-217F (25 ) 199*98*38mm (L*W*H) 0.77Kg; 18pcs/14.9Kg/0.81CUFT OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. No load power consumption<0.5W when RC+ & RC- (CN100 pin1,2) 0 ~ 8V or short. File Name:HRPG-200-SPEC 2010-09-17 200W Single Output with PFC Function Mechanical Specification HRPG-200 Case No.902E 197 series Unit:mm 9 1 9.5 2 3 85.5 4 5 8.2 3.5 80 7 6 7 Terminal Pin No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Assignment Pin No. DC OUTPUT -V 4,5 DC OUTPUT +V 6,7 3.5 LED CN100 SVR1 57.5 4- M 3 4.5 120 199 6.5 9 Pin No. Assignment RC+ 1 2 RC3 AUX 4 AUXG +S 5 -S 6 Mating Housing Terminal 3. 5 18.5 9.5 Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DS or equivalent 190 3.5 28.5 HRS DF11-6DS HRS DF11-**SC or equivalent or equivalent 13max. 28 150.75 3M3 Block Diagram AUX POWER EMI FILTER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC O.T.P. FG PFC CONTROL PWM CONTROL POWER SWITCHING O.L.P. RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. REMOTE CONTROL AUX AUXG +S +V -V -S 18 fosc :70KHz I/P RC+ RC- Derating Curve Output Derating VS Input Voltage Ta = 25 125 100 100 90 80 80 70 60 LOAD (%) 40 LOAD(%) 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 125 135 155 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:HRPG-200-SPEC 2010-09-17 38 98 15 26 200W Single Output with PFC Function Function Description of CN100 HRPG-200 series Pin No. Function Description RC+ Turns the output on and off by electrical or dry contact between pin 2 (RC-). Short: Power OFF, Open: Power ON. 1 RC- Remote control ground. 2 Auxiliary voltage output, 4.75~5.25V, reference to pin 4(AUXG). The maximum load current is 0.3A. This output has the built-in oring 3 AUX diodes and is not controlled by the "remote ON/OFF control". 4 5 AUXG Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to +S minimize noise pick-up effect. The maximum line drop compensation is 0.5V. -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 6 Function Manual 1.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between RC-(pin2) and RC+(pin1) SW ON (Short) SW OFF (Open) Output Status OFF ON CN100 1 2 RC+ AUX +S -S 5 SW RC- AUXG 6 -V -V +V +V CN100 135 246 LOAD + Fig 1.1 2.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. -V -V +V +V CN100 135 246 CN100 1 RC+ AUX +S -S 5 6 -S (Pin6) LOAD + +S (Pin5) Sense lines should be twisted in pairs 2 RC- AUXG Fig 2.1 File Name:HRPG-200-SPEC 2010-09-17 |
Price & Availability of HRPG-200-33 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |